MLCC High-Speed Testing and Sorting Equipment

Keyword:

Hotline consultation:

Detailed Description

China's first8-channel high-precision picoamp-levelAmmeter

Model ATV-CM3100
Discharge Impedance 1KQ/100Q/20Q(Switchable/Switchable)
Measurement Range 100DA、500DA、1nA、10nA、100nA、1uA、10uA、100uA、1mA、10mA
Measurement Accuracy ≤1nAGear: 3%F.S.
>1nAGear: 0.7%F.S.
Input Impedance 1KΩ/1002(Notchable/Switchable)
Contact Check 1pFAbove,Supports front and rearContact Check,Flexible configuration
Special Features Hardware self-diagnosis / built-in temperature compensation

 

China's first8-channel high-precision picoamp-levelAmmeter

Model ATV-CM6060(600V)/ATV-CM6100(1000V)
OutputVoltage CM6060:(1~600)VDC(0.1Vstep)(μV-level ripple/Ripple at μvlevel)
CM6100:(1~1000)VDC(0.1Vstep)(μV-level ripple/Ripple at μvlevel)
VoltageAccuracy 0.07%R.D.+10mV
Charging Current CM6060:2~50mA(1mAstep)(Accuracy/accuracy:0.5%+0.1mA)
CM6100:2~30mA(1mAstep)(Accuracy/accuracy:0.5%+0.1mA)
Charging Time 1~9999ms
Discharge Current CM6060:2~50mA(1mAstep)(Accuracy/accuracy:0.5%+0.1mA)
CM6100:2~30mA(1mAstep)(Accuracy/accuracy:0.5%+0.1mA)
Special Features Short-circuit defect identification caused by process defects
Confirmed short-circuit capacitors,Configurable whether subsequent stations are powered
Capacitor charge/discharge evaluation
Hardware self-diagnosis
Built-in temperature compensation
Output short-circuit protection
Flashover breakdown monitoring